Direct-to-chip cold plates1046 New Holland Ave, Lancaster
Advanced Cooling Technologies
Thermal solutions company whose data center products include coolant distribution units (CDUs), single- and two-phase liquid cold plates and manifolds; also…




Direct-to-chip cold plates1046 New Holland Ave, Lancaster
Thermal solutions company whose data center products include coolant distribution units (CDUs), single- and two-phase liquid cold plates and manifolds; also…

Direct-to-chip cold plates89 Access Rd Ste 27, Norwood
Manufactures thermal management solutions for AI and data centers, including liquid cold plates, coolant distribution units (CDUs), manifolds, pumped two-phase…

Chillers and heat rejection21 Waterway Ave Ste 300, The Woodlands
Manufactures and sells chillers, dry coolers, and heat exchangers for data centers and industrial applications, including liquid cooling commissioning and…

Data center cooling integrators4047 Market Pl, Flint
Provides industrial cooling solutions including megawatt-scale liquid cooling systems for data centers, modular mechanical rooms, heat rejection, and heat…

Immersion cooling11525 Stonehollow Dr #A-135, Austin
Green Revolution Cooling (GRC) provides immersion cooling systems (ICEraQ, ICETank) and ElectroSafe dielectric fluids for data centers, AI, HPC, and edge.

Immersion cooling7801 N Capital Of Texas Hwy Ste 230, Austin
Manufactures immersion cooling tanks (4U, 12U, 25U, 50U, ASIC Container) for data centers and ASIC mining, offering the MIDAS XCI System.

Cooling guides
Understand the ASHRAE Thermal Guidelines liquid cooling classes W17 through W45: supply temperature ranges, delta-T limits, and how to select the right class for your deployment.
Read guide: ASHRAE TC 9.9 Liquid Cooling Classes (W17-W45) Explained
Cooling guides
Compare the three main liquid cooling approaches for AI and high-density data centers: direct-to-chip cold plates, single-phase and two-phase immersion, and rear-door heat exchangers.
Read guide: Direct-to-Chip vs Immersion vs Rear-Door Cooling ComparedUnderstand the ASHRAE Thermal Guidelines liquid cooling classes W17 through W45: supply temperature ranges, delta-T limits, and how to select the right class for your deployment.
Compare the three main liquid cooling approaches for AI and high-density data centers: direct-to-chip cold plates, single-phase and two-phase immersion, and rear-door heat exchangers.
Step-by-step guide to sizing a CDU for direct-to-chip liquid cooling: heat load, flow rate, temperature rise, redundancy, and facility integration.
Market data for data center liquid cooling: $8.3B in 2027, $22.56B by 2032 (22.1% CAGR). Segments by technology, coolant, data center type, workload, and geography.
A practical checklist for data center operators and MEP engineers evaluating liquid cooling vendors: technical specs, warranties, fluid qualification, integration, and commercial terms.
Track how AI rack power densities have escalated from 30 kW to 150+ kW, driven by NVIDIA GB200 NVL72, AMD Helios, and hyperscale deployment data.
Compare brownfield retrofit and greenfield new-build approaches for liquid cooling: costs, timelines, technical constraints, and decision framework.
Understand Water Usage Effectiveness (WUE), Power Usage Effectiveness (PUE), and the trade-offs between water-free and evaporative cooling for AI data centers.
Chillers and heat rejection35
Direct-to-chip cold plates29
Data center cooling integrators21
Immersion cooling21CSCS, CC BY-SA 3.0, commons.wikimedia.org · Rolf Brink, CC BY-SA 4.0, commons.wikimedia.org · CSCS, CC BY-SA 3.0, commons.wikimedia.org · Votpuske, CC BY-SA 4.0, commons.wikimedia.org.